CalibCurve replaces the spreadsheet your calibration currently lives in. Validated regression, statistics computed to standard, acceptance criteria enforced rather than remembered, and a complete audit trail — on your own machine, with no internet connection required.
Calibration in Excel works right up until somebody asks a question about it. Who changed this cell? Which points were excluded, and on what grounds? Is that LOD computed the way the method says? Was this curve ever actually accepted, or did it just get used?
The workbook was built by someone who left in 2019. It has been copied eleven times. Two of the copies have a different LOD formula, and no one is certain which is right.
A point gets deleted because it "looked wrong". There is no record that it existed, no reason attached, and no statistical test that justified removing it.
The report is assembled by hand at the end, from numbers copied out of cells. Every transcription is an opportunity for an error that nothing will catch.
Method, data, calculation, review, export. The workflow is deliberately linear because calibration is a procedure, not an exploration.
Unweighted linear for standard work. Weighted 1/x and 1/x² where variance scales with concentration — LC-MS/MS, wide dynamic ranges. Four-parameter logistic for immunoassay and ELISA, where a straight line was never the right model.

A high R² hides a great deal. CalibCurve runs the diagnostics that actually detect a bad calibration: residual patterns, leverage, and influence — so a single point quietly bending the whole curve is flagged rather than averaged away.

QC levels are defined with the method, not decided afterwards. Low, mid and high controls are back-calculated against the curve, recovery and bias are computed, and the result is a pass or a fail against tolerances that were set in advance.

This is the part that matters for accreditation, and it is a deliberate design decision. CalibCurve will suggest a calibration status and offer wording for the QC summary — and it labels both, explicitly, as suggestions. The conclusion that goes into the report is written by the analyst, who is named in it.

Templates carry the regression model, units, QC levels and acceptance criteria for a technique, so a routine calibration starts configured rather than blank.
Paracetamol active-substance assay, caffeine in beverages, vitamin C. Linear and weighted models.
GC-FID and GC-MS: ethanol in extracts, methanol in production samples, acetone in air samples.
ICP-MS copper in drinking water, ICP-OES zinc in soil, AAS iron in alloys.
Nitrate and phosphate determination, BCA and Bradford protein assays.
ELISA protein quantification with 4PL, enzyme activity, qPCR DNA copy number.
pH electrode and conductivity calibration, ISE fluoride, Ca/Mg hardness, TOC in water.
Drug substance assays, dissolution testing, stability studies. QC and QA departments.
Water quality — heavy metals and anions — soil contamination, air quality monitoring.
Nutritional analysis, contaminant testing, routine quality control.
Therapeutic drug monitoring and biomarker quantification.
CROs and contract testing laboratories running many methods across many clients.
University laboratories and method development groups.
| Platform | Windows 10 and 11, 64-bit. Desktop application — no browser, no server component. |
| Installation | Signed installer. Installs to a normal user profile; administrator rights not required for standard use. |
| Connectivity | Fully offline. No internet connection required at any point, including activation. Suitable for isolated and validated laboratory networks. |
| Languages | German and English, switchable in the application. |
| Regression models | Unweighted linear · weighted 1/x · weighted 1/x² · four-parameter logistic (4PL) |
| Statistics | R², Pearson r, 95% confidence intervals, standard errors, full ANOVA, LOD/LOQ to DIN 32645, residual analysis, Cook's D, DFBETA, leverage |
| Data entry | Spreadsheet-style table with paste from Excel. Up to three replicates per level with automatic CV%. |
| Data storage | Local database. Calibrations, methods, analysts and instruments retained with timestamps. |
| Audit trail | Complete calibration history with analyst attribution, filterable and exportable to CSV. |
| Reporting | Configurable PDF reports — short or full — with embedded plots and a named analyst conclusion. |
| Compliance | Designed to support ISO 17025 documentation practice. LOD/LOQ per DIN 32645. |
| Licence | One-time purchase, perpetual, per installation. No subscription and no recurring fee. |
A note on compliance wording: CalibCurve is built to support documentation practice under ISO 17025 and computes LOD and LOQ according to DIN 32645. It is a calculation and documentation tool. Accreditation belongs to the laboratory, and validation for a specific regulated use remains the laboratory's responsibility.
It creates, evaluates and documents calibration curves for analytical instruments — replacing spreadsheet calibration with validated regression, standard statistics, enforced acceptance criteria and an audit trail. Used in pharmaceutical, environmental, food, clinical, industrial and academic laboratories.
No, and it is not meant to. A LIMS manages samples and workflows across a whole laboratory and starts around €5,000 per year. CalibCurve does the calibration part only, once, for €399. Many laboratories need rigorous calibration documentation without a LIMS implementation.
Unweighted linear, weighted 1/x and 1/x² for methods where variance scales with concentration such as LC-MS/MS, and four-parameter logistic (4PL) for immunoassay and ELISA.
According to DIN 32645 — 3.3·s/m for the limit of detection and 10·s/m for the limit of quantitation, where s is the residual standard deviation and m the slope.
Software cannot be ISO 17025 accredited; accreditation applies to the laboratory. CalibCurve is designed to support ISO 17025 documentation practice through its audit trail, analyst attribution, enforced acceptance criteria and standardised reporting. Validation for a specific regulated use remains the laboratory's responsibility.
No. CalibCurve runs entirely offline — no connection is required to install, activate or use it. Suitable for isolated and validated laboratory networks. No data leaves the machine.
No. One-time purchase of €399 for a perpetual licence per installation. No annual fee, no maintenance contract. Future major versions are optional paid upgrades, never a condition of continuing to use what you bought.
No. It computes the statistics and proposes a status — explicitly labelled as a suggestion. The analyst writes and owns the final interpretation, and is named in the report.
Perpetual licence per installation. No subscription, no annual maintenance fee, no cloud account. Online checkout is being set up and is pending payment-provider approval; until it is live, write to us and we will arrange invoicing, delivery and the licence key directly.